Accessible Bathroom CAD Blocks
Six wheelchair accessible blocks: a 2,185 x 2,085 mm restroom to the 2010 ADA Standards, a 1,500 x 2,200 mm corner WC to Approved Document M, a 1,700 x 1,800 mm WC room, a 2,200 x 2,200 mm bathroom with level-access shower, and a single accessible toilet and washbasin.
ADA bathroom CAD block to the 2010 ADA Standards
Doc M disabled toilet CAD block, Approved Document M Vol. 2
Accessible toilet CAD block with grab bars
Accessible bathroom with shower block
Disabled toilet with drop-down rail, single fixture
Accessible washbasin with knee space
- Units
- Millimetres (INSUNITS 4), scale 1:1
- Formats
- DWG 2010 · DXF R2010
- Opens in
- AutoCAD and AutoCAD LT 2010 or later, BricsCAD, ZWCAD and DraftSight. The DXF opens in most CAD programs.
- Views
- Plan view + Front elevation
- License
- Free for personal and commercial projects. License
These accessible bathroom CAD blocks come as six DWG and DXF files. Two follow a national code: an ADA restroom to the 2010 ADA Standards and a corner WC to Approved Document M, Volume 2 (England). Four are generic: a WC room, a bathroom with level-access shower, an accessible toilet and an accessible washbasin. Standard fixtures are in bathroom CAD blocks.
Accessible bathroom dimensions in the ADA and Doc M blocks
A test measures each code block's DXF against the clauses below. Where the code sets no figure, the block value is a drawing choice.
ADA bathroom CAD block (2010 ADA Standards)
The ADA sets no room size, so the room follows from the clearances: 2,185 x 2,085 mm clear (86 x 82 in).
- Turning space, 304.3.1 and 603.2.1. A 60 in (1,525 mm) circle. The block draws 1,525 mm, clear of the fixtures.
- Door, 404.2.3. 32 in (815 mm) clear width minimum. The leaf leaves 870 mm and opens outward, away from fixture clearances (603.2.3).
- Water closet, 604.2 and 604.4. Centerline 16 to 18 in (405 to 455 mm) from the side wall, seat 17 to 19 in (430 to 485 mm). Bowl centred at 450 mm, seat at 450 mm, closed lid at 470 mm.
- Clearance, 604.3.1. 60 x 56 in (1,525 x 1,420 mm) with no other fixture in it. The block draws a 1,525 x 1,423 mm zone and the lavatory starts 1,550 mm from the side wall.
- Grab bars, 604.5 and 609.4. Side bar 42 in (1,065 mm) and rear bar 36 in (915 mm) minimum, top of the gripping surface at 33 to 36 in (840 to 915 mm). The block has a 1,220 mm side bar and a 915 mm rear bar, 305 mm to the wall side of the centerline and 610 mm to the open side, both with the top at 870 mm.
- Lavatory, 606.3 and 306.3. Rim 34 in (865 mm) maximum, knee clearance up to 27 in (685 mm). The basin rim is at 860 mm, its underside at 690 mm, with a 760 x 1,220 mm forward approach space.
- Mirror, 603.3. Bottom of the reflecting surface 40 in (1,015 mm) maximum. The glass starts at 1,000 mm.
Doc M toilet layout (Approved Document M, Volume 2)
The block is the corner WC of Diagram 18 with right-hand transfer, for buildings other than dwellings.
- Room, 5.10(i) and Diagram 18. 1,500 x 2,200 mm minimum, which is the block size. If it is the only toilet in the building, 5.10(e) asks for 2,000 mm width and a standing-height basin, not covered here.
- Turning space, Diagram 18. A 1,500 x 1,500 mm square, drawn from the door.
- WC position, Diagrams 18 and 19. 750 mm from the back wall to the front of the pan, centre line 500 mm from wall A, 1,000 mm to the opposite wall for transfer and seat at 480 mm. The block matches all four.
- Grab rails, Diagrams 18 and 19 and 5.10(k). Drop-down rail 320 mm from the centre line and horizontal rails at 680 mm. Both rails sit at 680 mm and the 600 mm wall rail has its centre 400 mm from the WC centre line, so no second drop-down rail is needed.
- Basin and mirror, Diagrams 19 and 20. Rim at 720 to 740 mm, mirror from 600 mm to at least 1,600 mm. The finger rinse basin rim is at 730 mm and the mirror runs from 600 to 1,700 mm.
- Door, 3.10 and 5.10(g). 800 mm effective clear width in a new building, preferably opening outward. The block leaves 910 mm and opens outward, with a closing bar inside.
The generic blocks fall short of both codes. For the ADA, their 1,500 mm turning circle is 25 mm too small, bars sit at 700 to 760 mm with no rear bar, and only the single toilet is within 405 to 455 mm of the wall. For Doc M, the pans project 700 mm instead of 750 mm and the WC room is 400 mm too short.
All the blocks are a starting point, not a certified design. Check the current edition of the code and any state, local or regional rules, then confirm each figure before issuing drawings.
Grab bar CAD blocks and turning space
The generic WC room is 1,700 x 1,800 mm, with a wall-hung pan projecting 700 mm, its centre line 475 mm from the side wall, a drop-down rail, a fixed bar and a small basin. The bathroom is 2,200 x 2,200 mm and adds a 1,100 x 1,100 mm level-access shower with linear drain, fold-down seat and grab bar at 800 mm. Both have a 900 mm outward door and a dashed 1,500 mm turning circle.
Disabled toilet CAD block and accessible washbasin
The accessible toilet is the WC alone: 700 mm projection, centre line 450 mm from the side wall, seat at 480 mm, a 700 mm fixed bar and an 800 mm drop-down rail with toilet roll holder, both centred at 750 mm. The washbasin is 650 x 550 mm with a concave front, rim at 800 mm, 740 mm clear under the front edge, a long-lever mixer, two U-shaped grab bars and a tilting mirror.
Accessible bathroom CAD blocks in plan and elevation
Each file has a plan and an elevation block, such as CT_ACCESSIBLE_WC_ADA_PLAN, at 1:1 in millimetres. Fixtures are on P-FIXT and P-FIXT-DETL, doors on A-DOOR and A-DOOR-SWNG, walls on A-WALL and A-WALL-PATT and hidden parts on A-HIDN. In the code blocks, turning space and clearances are on A-ACCS-ZONE. Add the wheelchair user blocks to show the user, or see the toilet CAD blocks for a standard stall.